home *** CD-ROM | disk | FTP | other *** search
- Path: hunter.premier.net!usenet
- From: elias@premier.net (Elias Kougianos)
- Newsgroups: comp.dcom.modems
- Subject: Re: Supra 28.8 v32 Hangs up!!!!!!
- Date: Sun, 31 Mar 1996 02:07:50 GMT
- Organization: Premier One
- Message-ID: <315de84d.8654263@news.premier.net>
- References: <microfsh.827096870@las1.iastate.edu> <4jeqp1$76h@apollo.isisnet.com>
- NNTP-Posting-Host: elias.dialup.premier.net
- X-Newsreader: Forte Agent .99d/32.168
-
- On 28 Mar 1996 19:54:09 GMT, af898@ccn.cs.dal.ca (Danny Colquhoun)
- wrote:
-
-
- >here's an interesting suggestion... check for magnetic fields. My friend
- >had a crappy USR (aren't they all??) that would throw the on-hook
- >off-hook relay every few seconds. QUITE annoying habit, and sound, as it
- >would do this whenever the PCee was on.
- >
-
- My external supra 28.8 was freaking on me recently. Sudden hungups,
- funny noises, scrambled LEDs etc. I called the supra faxback service
- and one document suggested that the cause for this might be a faulty
- power supply. I bought a new ps fro Wal-mart and so far (3 days) not a
- single problem. I usually was unable to stay connected more that 4-5
- minutes.
-
- Later
-